A 68-year-old man presented to our general district hospital in December 2006 with the chief complaint of sore throat, which had started abruptly 2 hours earlier. The pain was described as intense with a stabbing character. He reported minimal improvement after being given 10 mg of morphine subcutaneously.

The patient did not report experiencing any cardiac or pulmonary discomfort, and he had no pertinent past medical history. His family history included one sister who had died of a ruptured aortic aneurysm. The patient was a non-smoker and denied any recent medication use.

Physical examination showed that the patient’s vital signs were stable, with a normal level of consciousness, a regular pulse of 61 beats/min, and a blood pressure equal at both arms of around 115/70 mmHg. He was slightly tachypnoeic and diaphoretic. An ear, nose and throat examination did not provide any diagnostic clues as to the cause of the pharyngeal pain. Findings of a cardiovascular examination were normal apart from an audible right carotid artery bruit. No other physical abnormalities were detected.

Results of laboratory tests were unremarkable, except for a markedly elevated d-dimer level (8.41 mg/L; upper limit of normal, 0.50 mg/L). Routine chest radiography was suggestive of mediastinal widening (Figure A). On the basis of these findings, a thoracic computed tomography scan was performed, which showed a 5.4 cm dissecting ascending aortic aneurysm (Figure B). The dissection involved the aortic root, ascending part of the aorta and aortic arch, and propagated into the right brachiocephalic trunk and left common carotid artery (Figure C). Transthoracic echocardiography additionally showed the presence of a bicuspid aortic valve with moderate grade 2/4 aortic insufficiency.

Thoracic aortic dissection was diagnosed, classified as a Stanford type A dissection, given the involvement of the ascending aorta. A congenital bicuspid aortic valve and an ascending aortic aneurysm were predisposing factors for aortic dissection.

The patient successfully underwent emergency surgery with graft replacement of the aortic valve and the dissected aortic segment.

A: Chest x-ray showing mediastinal widening. The upper normal mediastinal width is defined as a mediastinum to chest-width ratio of over 0.25, measured at the level of the aortic arch (illustrated by the length of the solid line); this is noticeably exceeded in our patient (dashed line).

B: Computed tomography scan showing an aneurysmatic dilatation of the ascending aorta with a classical dissection flap (black arrowhead) separating a true and false lumen.
C: Propagation of the dissection process into the supra-aortic vessels (white arrows).

The clinical presentation in our case was rather trivial, but the combined results from two basic investigations — an elevated d-dimer level and an abnormal chest x-ray — heightened our clinical suspicion for aortic dissection and led us to perform aortic imaging.

Thoracic aortic dissection generally results from a laceration of the intimal lining of the aorta. This allows blood leakage into the aortic wall resulting in a propagating separation of the aortic media, thereby creating a false blood-filled lumen.1 Hence, the major criterion for definitive diagnosis of aortic dissection includes visualisation of a so-called intimomedial flap that divides the aorta into a true and a false lumen. Several aortic imaging techniques can be used for this purpose, of which contrast-enhanced computed tomography (CT) and transoesophageal echocardiography (TOE) are the most feasible to perform in an emergency department setting.1,2 Moreover, these investigations help to localise the dissection, thereby allowing appropriate classification. Currently, the Stanford classification of aortic dissection is the most widely adopted system.1,2 This system has the virtue of merely dividing aortic dissection into two subtypes, depending on whether the ascending aorta is involved (type A) or not (type B).1,2

While the definitive diagnosis of aortic dissection is usually straightforward, making the initial clinical diagnosis can be extremely challenging. Aortic dissection is associated with a dramatic rate of misdiagnosis and delayed recognition.3 This is no doubt partially explained by the highly variable clinical presentation of the condition.

Our case is a striking illustration of why acute aortic dissection is colourfully called a “clinical chameleon”.1 Although most patients with aortic dissection present with severe chest or back pain (Box 1), the pain can be variably localised to the neck, jaw or throat.4 Throat pain occurs most often in cases of a dissection of the aortic arch, particularly when the supra-aortic vessels are involved. Our patient complained only of a sore throat, and denied having thoracic pain. Only two similar cases have been previously reported.5,6

Moreover, findings on physical examination can be very subtle.1 Classical signs consistent with the diagnosis of thoracic aortic dissection, such as an aortic insufficiency murmur or decreased femoral arterial pulsation, were not present in our patient. According to the International Registry of Acute Aortic Dissection,7 these so-called typical findings are infrequently detected during physical examination (Box 1). In our case, the only notable features of the physical examination were diaphoresis and a right carotid artery murmur. The latter was presumably the result of propagation of the dissection into the right brachiocephalic trunk.

Because symptoms and signs of aortic dissection can be diverse and sometimes treacherously trivial, the initial diagnostic suspicion might rely on abnormalities observed during the basal diagnostic work-up. This routinely consists of laboratory testing with d-dimer analysis and chest radiography.

d-dimer analysis has only recently come to the fore, with several studies focusing on the stringent association between the d-dimer level and aortic dissection.3,8,9 The pathophysiological mechanism for this relationship is well explained by the release of tissue factor from the dissected aortic wall. This sets off a cascade of events — activation of the extrinsic coagulation system, generation of fibrin, and secondary fibrinolysis with d-dimer formation.8 The d-dimer assay is reported to have an excellent sensitivity and negative predictive value for aortic dissection (Box 1). The quoted sensitivity is equal for both types of dissection, although absolute d-dimer values tend to be higher in type A aortic dissections as they are usually more extended.10 Given its high sensitivity and negative predictive value, d-dimer testing is an attractive tool for the diagnostic work-up of aortic dissection, particularly in the setting of a low pretest probability for aortic dissection. In such cases, a normal d-dimer result can reliably exclude the presence of aortic dissection, hence obviating the need for further investigations.9,10

Besides elevation of the d-dimer level, the clinical suspicion for aortic dissection should also be heightened if the chest radiograph is abnormal (Box 1). Mediastinal widening (relative mediastinum to chest-width ratio > 0.25;11 Figure A) is the most common radiographic finding in aortic dissection.7 Of note, absolute estimations of the mediastinal width are practically inaccurate, as these measurements are influenced by the distance between the roentgenographic source and the thorax.12 It is worth mentioning that one in three patients with aortic dissection has a normal chest x-ray.11 Thus, relying on chest radiography alone as the initial diagnostic modality is inefficient as it clearly carries a high risk of misdiagnosis.

When readily available, contrast-enhanced CT and TOE are the preferred imaging modalities in an acute care setting. Both investigations have a comparable diagnostic accuracy and allow a definitive diagnosis of aortic dissection to be established.1,2 However, the diagnosis must first be suspected before it can be confirmed — this case serves as a reminder of this life-threatening condition’s wide variability in clinical presentation, and the need to maintain continuing vigilance.

  • Sébastien Anguille1
  • Aurélie M Derweduwen2
  • Jeroen Lenz1
  • Luc Vanuytsel3
  • Frank J Cools4

  • 1 Department of Internal Medicine, Antwerp University Hospital, Edegem, Antwerp, Belgium.
  • 2 Department of Internal Medicine, University Hospital Gasthuisberg, Leuven, Belgium.
  • 3 Department of Radiotherapy, H.-Hartziekenhuis Roeselare-Menen, Roeselare, Belgium.
  • 4 Department of Internal Medicine, AZ Klina, Brasschaat, Belgium.


Correspondence: sebastien.anguille@uza.be

Acknowledgements: 

We wish to pay tribute to Luc Vanuytsel, coauthor of this article, who died suddenly during the internal review phase of this manuscript.

Competing interests:

None identified.

  • 1. Rehders T, Ince H, Nienaber CA. Aortic dissection: from aetiology to therapeutic management. Medicine 2006; 34: 296-301.
  • 2. Golledge J, Eagle KA. Acute aortic dissection. Lancet 2008; 372: 55-66.
  • 3. Sutherland A, Escano J, Coon TP. d-dimer as the sole screening test for acute aortic dissection: a review of the literature. Ann Emerg Med 2008; 52: 339-343.
  • 4. Vilacosta I, Román JA. Acute aortic syndrome. Heart 2001; 85: 365-368.
  • 5. Averbeck T, Hemmanouil I, Bredt M, Stover T. Therapy refractory throat pain. Dissecting aneurysm of the aorta with cardiac tamponade. HNO 2002; 50: 946-947.
  • 6. Liu WP, Ng KC. Acute thoracic aortic dissection presenting as sore throat: report of a case. Yale J Biol Med 2004; 77: 53-58.
  • 7. Hagan PG, Nienaber CA, Isselbacher EM, et al. The International Registry of Acute Aortic Dissection (IRAD): new insights into an old disease. JAMA 2000; 283: 897-903.
  • 8. Marill KA. Serum d-dimer is a sensitive test for the detection of acute aortic dissection: a pooled meta-analysis. J Emerg Med 2008; 34: 367-376.
  • 9. Sodeck G, Domanovits H, Schillinger M, et al. d-dimer in ruling out acute aortic dissection: a systematic review and prospective cohort study. Eur Heart J 2007; 28: 3067-3075.
  • 10. Ohlmann P, Faure A, Morel O, et al. Diagnostic and prognostic value of circulating d-dimers in patients with acute aortic dissection. Crit Care Med 2006; 34: 1358-1364.
  • 11. von Kodolitsch Y, Nienaber C A, Dieckmann C, et al. Chest radiography for the diagnosis of acute aortic syndrome. Am J Med 2004; 116: 73-77.
  • 12. Gleeson CE, Spedding RL, Harding LA, Caplan M. The mediastinum — is it wide? Emerg Med J 2001; 18: 183-185.

Author

remove_circle_outline Delete Author
add_circle_outline Add Author

Comment
Do you have any competing interests to declare? *

I/we agree to assign copyright to the Medical Journal of Australia and agree to the Conditions of publication *
I/we agree to the Terms of use of the Medical Journal of Australia *
Email me when people comment on this article

Online responses are no longer available. Please refer to our instructions for authors page for more information.