Diagnostic Dilemmas

A case of discordant HbA1c: a method-dependent error

Goce Dimeski, Carel J Pretorius, Anthony W Russell, Stephen P Miller, Robert J Bird and Jacobus P J Ungerer
MJA 2009; 191 (6): 347-349

Although glycated haemoglobin (HbA1c) has become the key biochemical marker of long-term glycaemic control, analytical method-dependent differences in results can occur when haemoglobin variants are present or HbA1c is reduced by decreased red cell survival. When the measured HbA1c level is discordant with the patient’s blood glucose measurements and clinical status, fructosamine is an alternative biochemical marker that can provide a more accurate estimate of the glycaemic control and enable clinicians to appropriately manage patients.

Clinical record

A 65-year-old, centrally obese man (body mass index, 32.7 kg/m2) with a 23-year history of type 2 diabetes mellitus was referred to a diabetes clinic in January 2008 for stabilisation of his blood sugar levels. His diabetes was complicated by ischaemic heart disease, peripheral vascular disease, hypertension, dyslipidaemia, and stage 3 chronic kidney disease. His glycated haemoglobin (HbA1c) level on referral was 11.0%, measured using an ion-exchange chromatography (IEC) method on a Bio-Rad Variant II analyser (Bio-Rad Laboratories, Sydney, NSW), and the laboratory fasting glucose measurement was 19.3 mmol/L (Box 1). Both these results were consistent with the patient’s home blood glucose measurements (> 10 mmol/L).

Home | Issues | eMJA shop | Terms of use | Classifieds | More... | Contact | Topics | Search

The Medical Journal of Australia    eMJA  

©The Medical Journal of Australia 2009 www.mja.com.au PRINT ISSN: 0025-729X ONLINE ISSN: 1326-5377